Coax Cables 50 Ohm - Antennas
Table of Coax Cables (Attenuation, Impedance, Capacity)
Connectors
BNC |
 |
 |
 |
LAN, Video, Antenna |
TNC |
 |
 |
 |
LAN, Video, Antenna |
N-Type |
 |
 |
 |
Video, Antenna |
Twinax |
 |
 |
 |
Twinax |
| |

Stecker-Profi |
COAX Cables
Coaxial cable is a shielded one-conductor cable with the conductor embedded in a di-electricum, which is wrapped in foil or a braided shield. It is called coaxial because it includes one physical channel that carries the signal, surrounded by a layer of insulation and by another concentric physical channel, both running along the same axis.
Some of the newer cables for wireless systems (50 Ohms):
AIRCELL 7
AIRCELL 7 is a 7mm low loss extra flexible cable. It is excellent for HF operation and usable up into the microwave region. This cable has a flexible stranded center conductor, surrounded by gas injected PE foam. The UV-protecting outer jacket is made of PVC.
Specifications: |  |
Impedance |
50 Ohms |
Centre Conductor |
stranded copper 19 x 0,37 - 1,85mm |
Dielectric |
PE-Compound |
Outer conductor 1 |
PE-coated copperfoil, 100% coverage |
Outer conductor 2 |
Copperbraid, 72% coverage |
Diameter over sheath |
7,3 mm |
Velocity factor |
0,85 |
Capacity per meter |
74 pF |
Min. bending radius |
25 mm |
Aircell 7 Loss (dB / 100m) |
Frequency
|
Damping (dB / 100m)
|
5 MHz |
1,7 |
10 MHz |
2,2 |
50 MHz |
4,8 |
100 MHz |
6,6 |
144 MHz |
7,9 |
200 MHz |
9,2 |
432 MHz |
14,1 |
500 MHz |
15,5 |
1000 MHz |
22,5 |
1296 MHz |
26,1 |
1500 MHz |
28,8 |
2000 MHz |
33,8 |
2320 MHz |
37,9 |
2400 MHz |
39,9 |
3000 MHz |
43,8 |
ECOFLEX 10
ECOFLEX 10 is a highly flexible 10 mm coaxial cable for use in the frequency range up to 4 GHz. It has a stranded centre conductor, formed by 7 pure copper wires and a PE-LLC dielectric. The EMI screening immunity of > 85 db @1 GHz is achieved through double shielding by the use an overlapping PE- stabilized copperfoil and a copperbraid with 72% coverage.
Specifications: |
Impedance |
50 Ohms |
Centre Conductor |
stranded copper 7x1.0mm |
Dielectric |
PE-Compound
|
Outer conductor 1 |
PE-coated copperfoil, coverage 100% |
Outer conductor 2 |
Copperbraid, coverage 72% |
Diameter over sheath |
10,2 mm |
Velocity factor |
0,86 |
Capacity per meter |
77 pF |
Min. bending radius |
40 mm |
ECOFLEX® 10 Loss (dB / 100m) |
Frequency |
Damping (dB / 100m) |
5 MHz |
0,8 |
10 MHz |
1,2 |
50 MHz |
2,8 |
100 MHz |
4,0 |
145 MHz |
4,8 |
200 MHz |
5,9 |
432 MHz |
8,9 |
500 MHz |
9,6 |
1000 MHz |
14,2 |
1296 MHz |
16,5 |
1500 MHz |
17,9 |
2000 MHz |
21,2 |
2320 MHz |
23,1 |
2400 MHz |
23,6 |
3000 MHz |
27,0 |
4000 MHz |
32,2 |
|